Wearable IoT-Based Soldier Health and Safety Monitoring System
Keywords:
DS18B20, FastAPI, Panic button, SENTINEL dashboard, Soldier health monitoring, Wearable IoT, WebSocketAbstract
Continuous observation of a soldier’s physiological state and surroundings can shorten the time between the onset of a hazard and the response to it. This article presents the design and implementation of a wearable IoT-based soldier health and safety monitoring prototype. An ESP32 DevKit V1 acquires heart rate from a MAX30102 photoplethysmography sensor, body and ambient temperature from two DS18B20 digital sensors, and a combustible-gas/smoke level from an MQ-2 module, and it reads a physical panic button. Readings are shown on an SSD1306 OLED, and a buzzer gives a local alert. The firmware emits one JSON record per second over USB serial; a Python reader forwards it to a FastAPI backend that stores readings and alerts in SQLite and pushes live updates over WebSocket to a React–Vite control-room dashboard named SENTINEL, which raises browser notifications and records operator acknowledgement. In controlled prototype tests, MQ-2 raw ADC values of about 944–1008 (estimated 1.14–1.22 V) were observed, panic activation produced persistent PANIC alert records (IDs 23 and 24) that were acknowledged by the control-room operator, and Chrome emergency notifications were displayed. A Serial Monitor capture of seven consecutive records from the assembled node reported heart rate of 112–120 BPM, skin-contact body temperature of 36.5°C–36.9°C, ambient temperature of 28.5°C–29.6°C, MQ-2 raw ADC values of 2464–2501 (estimated 2.978–3.023 V) and both true and false panic states; these values were not compared with any reference instrument. These are demonstration observations, not statistical results. No accuracy, calibration, response-time, or clinical claims are made; the system is a working prototype, not a certified medical or military device. Reference-based accuracy validation of heart rate and temperature, MQ-2 calibration, and real-world field testing remain future work, and the wired USB link between the node and the host limits mobility and remote use. The work gives a transparent, low-cost, and reproducible architecture for soldier health and safety monitoring.
References
J. Gubbi, R. Buyya, S. Marusic, and M. Palaniswami, "Internet of Things (IoT): A vision, architectural elements, and future directions," Future Generation Computer Systems, vol. 29, no. 7, pp. 1645–1660, Sep. 2013.
Espressif Systems, "ESP32-WROOM-32 Datasheet," Espressif Systems, Version 3.8, Sep. 2026.
J. Allen, "Photoplethysmography and its application in clinical physiological measurement," Physiological Measurement, vol. 28, no. 3, pp. R1–R39, Mar. 2007.
A. Gondalia, D. Dixit, S. Parashar, V. Raghava, A. Sengupta, and V. R. Sarobin, "IoT-based Healthcare Monitoring System for War Soldiers using Machine Learning," Procedia Computer Science, vol. 133, pp. 1005–1013, 2018.
R. Jinad, K. Gupta, D. Oladimeji, A. Rasheed, and C. Varol, "Real-time anomaly detection in physiological parameters: A multi-squad monitoring and communication architecture," Sensors, vol. 25, no. 3, Art. no. 929, Feb. 2025.
N. Sirisha, V. Revathi, A. Albawi, N. Gupta, N. Singh, and M. Krishnamoorthy, "AI-driven predictive health monitoring and early warning systems for enhanced soldier safety in IoT-enabled wearable devices," E3S Web of Conferences, vol. 619, 2025.
M. Gone, S. Ghodse, Y. Khaserao, A. Kulkarni, and A. Chaphadkar, "Real-Time Soldier Health Monitoring System Using IoT and Blynk Cloud," SSRN, 2024.
V. Annapoorani, P. Rathna, C. Priyanka, B. Maheshwari, and E. Leela, "Health Monitoring and Tracking System for Soldiers Using Internet of Things (IoT)," International Journal of Advanced Research in Science, Communication and Technology, vol. 12, no. 2, pp. 58–61, Dec. 2021.
S. Nanditha, K. Deepaligowda, and P. R. Kowshik, "IoT Based Health Monitoring and Location Tracking System for Soldiers," International Research Journal of Engineering and Technology (IRJET), vol. 8, no. 10, pp. 1896–1906, Oct. 2021.
S. S. Patil, A. B. Patil, and A. S. Mali, "Soldier tracking and health monitoring system," Int. J. Engineering and Management Research (IJEMR), vol. 13, no. 2, pp. 55–58, Apr. 2023.
O. Khandelot, V. Rotkar, M. Chauhan, and P. Ingawale, "Arduino-based soldier location and health tracking system," Int. J. Innovative Science and Research Technology, vol. 7, no. 11, Nov. 2022.
T. Tamura, Y. Maeda, M. Sekine, and M. Yoshida, "Wearable photoplethysmographic sensors—Past and present," Electronics, vol. 3, no. 2, pp. 282–302, 2014.
Hanwei Electronics Co., Ltd., "Technical Data: MQ-2 Gas Sensor," Hanwei Electronics CO., Ltd., Nov. 07, 2018.
I. Fette and A. Melnikov, “RFC 6455: The WebSocket Protocol,” Dec. 2011.
FastAPI, “FastAPI,” fastapi.tiangolo.com.
SQLite, "SQLite Documentation," SQLite.
Maxim Integrated, "MAX30102: High-Sensitivity Pulse Oximeter and Heart-Rate Sensor for Wearable Health," Datasheet, Oct. 2018.
Maxim Integrated, "DS18B20: Programmable Resolution 1-Wire Digital Thermometer," Datasheet, Jul. 2019.
Solomon Systech Limited, "SSD1306: 128 × 64 Dot Matrix OLED/PLED Segment/Common Driver with Controller," Semiconductor Technical Data, pp. 1-64, Jul. 2010.