CareLink: IoT-Based Intelligent Monitoring and Assistance System for Alzheimer’s Patients and Senior Citizens

Authors

  • Manjunath Patil
  • Omkar Magadum
  • Raghavendra Maggavi
  • Samruddhi Sattikar
  • Omkar Bokade

Keywords:

Alzheimer’s disease, Blynk, Geofencing, GPS tracking, Global System for Mobile Communications (GSM), IoT

Abstract

Alzheimer’s disease and age-related cognitive decline can increase the risk of wandering, falls, and delayed emergency assistance. CareLink is a wearable Internet of Things (IoT) safety system that connects patients with caretakers. Based on an ESP32, it detects falls using a four-stage threshold algorithm applied to MPU6050 inertial data, obtains location through GPS, monitors heart rate using a photoplethysmography sensor, and measures temperature using a DS18B20. Fall and geofence events trigger GSM-based SMS alerts containing patient status and coordinates, while routine vital signs are transmitted over Wi-Fi to the Blynk application. In trials covering six activities (20 trials per activity), fall-detection accuracy ranged from 85% to 95%. Temperature and heart-rate sensors were also evaluated on 50 participants against reference devices. The prototype demonstrates integrated wearable monitoring and emergency alerting; quantitative communication delay, GPS error, and sensor agreement metrics require further characterization and are identified for completion in the revised results.

References

Alzheimer’s Association, “2024 Alzheimer’s disease facts and figures,” Alzheimer’s & Dementia, vol. 20, no. 5, pp. 3708–3821, Apr. 2024.

J. Gubbi, R. Buyya, S. Marusic and M. Palaniswami, “Internet of Things (IoT): A vision, architectural elements, and future directions,” Future Generation Computer Systems, vol. 29, no. 7, pp. 1645–1660, Sep. 2013.

S. M. R. Islam, D. Kwak, M. H. Kabir, M. Hossain and K.-S. Kwak, “The Internet of Things for health care: A comprehensive survey,” IEEE Access, vol. 3, pp. 678–708, Jun. 2015.

S. Salvi, L. Garg and V. Gurupur, “Stage-wise IoT solutions for Alzheimer’s disease: A systematic review of detection, monitoring and assistive technologies,” Sensors, vol. 25, no. 17, Aug. 2025.

Y. B. Fadhel, M. Rinchi and K. Al-Haddad, "Smart Device for Monitoring Persons with Alzheimer Disease," 2024 IEEE International Conference on Artificial Intelligence & Green Energy (ICAIGE), Yasmine Hammamet, Tunisia, Oct. 2024, pp. 1-6.

S. Son et al., “Potentially modifiable dementia risk factors in Canada: An analysis of Canadian Longitudinal Study on Aging with a multi-country comparison,” Journal of Prevention of Alzheimer’s Disease, vol. 11, no. 5, pp. 1490–1499, Oct. 2024.

Sarita, T. Choudhury, S. Mukherjee, C. Dutta, A. Sharma and A. Sar, “A wearable device for assistance of Alzheimer’s disease with computer aided diagnosis,” EAI Endorsed Transactions on Pervasive Health and Technology, vol. 10, mar. 2024.

P. Gholap, A. Wadekar, A. Wale, S. Wakale and R. Waghachaware, “IoT based GPS tracking for dementia patient,” International Journal of Advanced Research in Science, Communication and Technology (IJARSCT), vol. 3, no. 2, pp. 81-88, Oct. 2023.

Abhishek, A. P. N, A. G. C T, B. H. V and S. Kanithan, "Smart Biomedical Assisted System for Alzheimer Patient," 2023 7th International Conference on Design Innovation for 3 Cs Compute Communicate Control (ICDI3C), Karnataka, India, Nov. 2023, pp. 132-136.

W. Salehi, G. Gupta, S. Bhatia, D. Koundal, A. Mashat and A. Belay, “IoT-based wearable devices for patients suffering from Alzheimer disease,” Contrast Media & Molecular Imaging, pp. 1-15, Apr. 2022.

S. B. Kwon, J. -H. Park, C. Kwon, H. J. Kong, J. Y. Hwang and H. C. Kim, "An Energy-Efficient Algorithm for Classification of Fall Types Using a Wearable Sensor," in IEEE Access, vol. 7, pp. 31321-31329, 2019.

A. Cejudo, M. Arrojo, C. Martín and A. Almeida, “AI and Wearables for Early Detection of Cognitive Impairment and Dementia: Systematic Review,” Journal of Medical Internet Research, vol. 28, Feb. 2026.

D. Pugliese, G. Longo, A. di Palma, A. Rashid, A. Rago and G. Sciddurlo, “A Low-Power Wearable IoMT System for Geofencing and Health Monitoring of Care-Dependent Individuals: Design, Implementation and Field Testing,” IET Wireless Sensor Systems, vol. 16, no. 1, Apr. 2026.

J. Allen, “Photoplethysmography and its application in clinical physiological measurement,” Physiological Measurement, vol. 28, no. 3, pp. R1–R39, Feb. 2007.

R. W. Sinnott, “Virtues of the Haversine,” Sky and Telescope, vol. 68, p. 159, Aug. 1984.

A. K. Bourke, J. V. O’Brien and G. M. Lyons, “Evaluation of a threshold-based tri-axial accelerometer fall detection algorithm,” Gait & Posture, vol. 26, no. 2, pp. 194–199, Jul. 2007.

R. Igual, C. Medrano and I. Plaza, “Challenges, issues and trends in fall detection systems,” BioMedical Engineering OnLine, vol. 12, art. 66, Jul. 2013.

Published

2026-11-26

How to Cite

Manjunath Patil, Omkar Magadum, Raghavendra Maggavi, Samruddhi Sattikar, & Omkar Bokade. (2026). CareLink: IoT-Based Intelligent Monitoring and Assistance System for Alzheimer’s Patients and Senior Citizens. Journal of Electronics and Telecommunication System Engineering, 38–50. Retrieved from https://matjournals.net/engineering/index.php/JoETSE/article/view/4523